Pressure Points On Your Foot

Pressure Points On Your Foot . They are believed to have multiple benefits, including reducing stress, aiding digestion, and promoting sound sleep. You can see that it is in the center of inside ankle bone and achilles’ tendon. Foot massage acupressure points diagram from www.anatomynote.com Your feet can be pampered by massaging it’s pressure points, thereby reducing the chronic pain that could be felt around it. It involves applying pressure to different points on the bottom of the foot. Usually occurs in group between 40 and 60 years old.

Pressure Drop Ratio Factor Xt


Pressure Drop Ratio Factor Xt. If xt =0.9 then x=0.9 and flow through the valve becomes choked at p2/p1=0.1 This is the δp/p1 at which there is no longer any flow increase.

industrial valves manufacturers industrial valves market
industrial valves manufacturers industrial valves market from www.itcengco.com

From what i can figure out, you need the xt value to find the cv/kv value. Equally, critical pressure drop is 42% of the upstream pressure, that is, a pressure drop ratio of 0.42. Inlet compressibility factor ­ “0.01” j.

The Valve Pressure Drop Ratio Is Measured Experimentally And Is Tabulated In Valve Manufacturers Catalogues.


X t = pressure drop ratio factor (this value is supplied by the constructor of the valve in product brochure). Inlet pressure ­ “100” d. Y cvm sgq y = k x t p po 3.

Flows 7.5 Gpm @ 5Psi Differential (See Table, Next Page)


This value is used to calculate the choke point (similar to fl in liquid sizing). Note, that xt includes some flow increase after the onset of choked flow due This is the δp/p1 at which there is no longer any flow increase.

700 Psig At 70 Deg F For A 3/4 X 24 End To End Hose, 19 3/4 In Live Length With 80 Corrugations.


F(, is the ratio of specific heat ratio of gas, k, to chat of air, 1.4. X sizing is the ratio of the pressure drop across the valve to the inlet pressure of the valve for subsonic flow: When control valve is installed with fittings, replace x t by x tp, x tp 2= 2 1 4 2 4 2 2 1 207.47 1 1 v v v t p t d cv do d x f x

But It Says In The Emerson Control Valve Handbook That You Should Pick The Xt Value You.


When x == fy xt, then q == qmax(t) and y == 0,667. Pressure drop ratio factor, x t. Y^ is larger than 0.667

Inlet Compressibility Factor ­ “0.01” J.


At low pressure drop ratios, the flow is the same through both valves, but as the pressure drop ratio increases, the flow in the butterfly valve starts aiming toward choked flow before the flow in the globe valve does. From what i can figure out, you need the xt value to find the cv/kv value. Pressure drop ratio factor (xt) ­ “0.65” k.